IBM Braindumps

Real Exam Questions Dumps With Their Answers

'C9510-401 Actual Test'

C9510-401 Dumps


You can pass easily using C9510-401 dumps. We keep postings these C9510-401 exam questions answers on this site regularly. Some search words are C9510-401 braindumps, past papers, study material and C9510-401 dumps practice test.

C9510-401 | A system administrator needs to create a cell…

Question: 3

A system administrator needs to create a cell for a test environment. The administrator uses the Profile Management Tool (PMT) to create the deployment manager profile using the advanced profile creation option and creates a custom profile using the typical profile creation option. The administrator examines the log files for the custom profile creation and sees an INSTCONFFAIL message indicating the deployment manager was not running during the custom profile creation. How should the administrator fix this?

A. Delete the custom profile.
Start the deployment manager.
Create the custom profile again.
B. Start the deployment manager.
Use PMT to re-create the custom profile.
C. Use the syncNode command to synchronize the node.
D. Run the addNode command to federate the custom profile.

Answer: A

C9510-401 | A system administrator needs to install WebSphere Application…

Question: 2

A system administrator needs to install WebSphere Application Server using response files, so that silent install can be done. The administrator has ensured that all required prerequisites have already been installed and, has downloaded and expanded the required WebSphere Application Server installation files. What can the administrator run to install the product?

A. install -options responsefile.xml -silent
B. install -acceptLicense -options responsefile.xml -silent
C. install -acceptLicense input responsefile.xml -log logfile.txt
D. IBMIM -acceptLicense -input responsefile.xml -log logfile.txt

Answer: A

C9510-401 | A WebSphere Application Server cell was configured with…

Question: 1

A WebSphere Application Server cell was configured with a deployment manager node and a custom node. An operator manually changed some configuration files in the custom node, and the node became out of synch with the master repository. The system administrator used the Synchronize button in the system administration session of the Integrated Solutions Console (ISC) to try to resynchronize the node, but the node remained out of sync. What should the administrator do to fix it?

A. Use the Full Resynchronize button.
B. Invoke “sync” operation on NodeSync MBean.
C. Recreate the custom profile with the same name without deleting the node.
D. Manually copy all the deployment manager configuration files to the custom node.

Answer: A